Three Phase Smart Electricity Meter
The Three Phase Smart SED302 Meter delivers accurate energy measurement, multi-tariff billing, power quality monitoring, and secure smart connectivity.
Features
bolt
Three phase, 3×230/400 V · 5 A basic, 100 A max current
dialpad
STS keypad · prepayment recharge and data query
cell_tower
CAT.1 + 2G and RS485 · plus optical port for local access
shield
IP54 enclosure · multi-point sealing and tamper detection
Everything you need to know
Open each section for features, connectivity, standards and technical data.
Download Brochure01Main FeaturesMain Features
Front View Description
monitor
Display
The meter features an LCD display with 8 characters and up to 2 decimal points, providing real-time information on energy consumption, voltage, and current. The backlight is white for easy readability.
touch_app
Data Query Button
Compliant display and demand button are available to allow users to interact with the meter, query data, and navigate menus. Additionally, sound feedback is provided when buttons are pressed.
info
Meter Information
Essential information, such as the serial number and model details, is provided on the front and module covers, aiding identification and usage.
dialpad
STS Keypad
The meter includes a keypad used for querying data information and recharge.
Major Application
receipt_long
Load Profiles and Billing
It records load profiles at 15-minute intervals for up to 100 days and supports monthly billing data storage for 12 months, providing detailed consumption records. Billing is reset automatically at the beginning of each month, with configurable settings.
nest_clock_farsight_analog
Real-Time Clock Unit
The meter has a real-time clock unit with an accuracy of less than 0.5 seconds per day, maintaining precise time for billing and event logging.
Hardware and Structure
backup
Power and Backup
A super capacitor supports the "last gasp" function for sending final data during power outages, and internal/external batteries provide reliable backup power.
layers
Cover and Terminal Materials
The meter housing, including the cover, terminal cover, and terminal block, is made of polycarbonate (PC), with a white color for the main body and a transparent terminal cover. The terminal materials are copper, with nickel coating, and zinc-coated iron screws to ensure durability.
water_drop
Dust and Water Protection
The meter is rated with IP54 protection, providing resistance against dust and water, ensuring durability in various environmental conditions.
shield
Sealing and Tamper Protection
The meter is equipped with multiple seal positions (top cover, terminal cover, module covers, MD button) to prevent tampering. The sealing material is aluminum caps by default.
The Three Phase (SED302) Smart Electricity Meter offers advanced measurement, billing, and communication features for efficient energy usage, monitoring, and management, making it suitable for modern energy infrastructures.

02Communication TechnologiesCommunication Technologies
settings_input_component
Optical Communication Interface
An optical communication interface is present for data exchange. This interface might be used for data reading, configuration and firmware upgrade.
nest_remote_comfort_sensor
Remote Communication and Control
Equipped with RS485 and wireless communication (CAT.1+2G) with a short antenna, it supports two-way communication, enhancing control and data collection capabilities.
Communication
| Local communication | RS485 | Comply | |
| Optical port (with iron) | Comply | ||
| AMI communication | Wireless | Module type | CAT.1+2G |
| Antenna | Short | ||
| UIU communication | PLC | / | |
03Standards and CompliancesStandards and Compliances
Chat_Bubble
DLMS/COSEM Protocol Compliance:
The meter complies with DLMS/COSEM standards, ensuring compatibility and inter operability with other smart metering systems.
REFERENCE STANDARD
| IEC |
IEC 62053-21 IEC 62053-23 IEC 62052-11 |
| Protocol | DLMS/COSEM |

04Technical DataTechnical Data
BASIC PARAMETER
| Accuracy | Active | IEC Class 1 |
| Reactive | IEC Class 2 | |
| Structure | Structure Type | BS |
| Wiring connection | L1L1L2L2L3L3NN(3P4W) | |
| Voltage | Nominal voltage Un | 3*230/400V-3P4W |
| Operating range | 0.6Un--1.2Un | |
| Current | Basic current I b | 5A |
| Max current Imax | 100A | |
| Active I start | 0.4%Ib(IEC Class1 Direct) | |
| Reactive I start | 0.5%Ib(IEC Class 2 Direct) | |
| Frequency | Nominal frequency Fn | 50Hz |
| Operating range | 50Hz±5% | |
| Meter constant | Active (imp/kWh) | 1000 |
| Reactive (imp/kVarh) | 1000 |
OUTPUT UNITS
| Display | Type | LCD |
| Value display character number | 8 | |
| Max decimal | 2 | |
| Backlight | White | |
| LED | Active pulse | Red |
| Reactive pulse | Red | |
| Alarm | Red | |
| Credit(2 color) | Red & Green | |
| Latch Relay | Pole number | 3 Pole |
| Maximum Switching Current | 120A | |
| Beep | Comply | |
INPUT UNITS
|
Key &Detection |
Display button |
Comply |
|
Billing button |
Comply |
|
|
STS keypad |
Comply |
|
|
Meter cover |
Comply |
|
|
Terminal cover |
Comply |
|
|
Module cover |
Comply |
|
|
Module cover 2 |
Comply |
|
|
Magnetic |
Comply |
|
|
Others |
display button and demand reset button require sound feedback |

STRUCTURE
| Cover | Material | PC |
| Color | White | |
| Base cover | Material | PC |
| Color | White | |
| Terminal cover | Material | PC |
| Color | Transparent | |
| Type | Extended | |
| Terminal block | Block material | PC |
| Color | White | |
| Wiring clamping type | Clamp cage | |
| Terminal material | Copper | |
| Terminal material coating | Nickel | |
| Clamping screw material | Iron(Default) | |
| Clamping screw coating | Zinc | |
| Dust and water protection | IP54(Default) | |
| missing dimension | 266.5 x 168 x 84.5 | |
| Sealing | Type | Screw(Default) |
| Seals material | plastic | |
| Seals fixed position1 | Top cover | |
| Seals fixed position2 | Terminal cover | |
| Seals fixed position3 | Module cover (CAT.1+2G module cover) | |
| Seals fixed position3 | Module cover 2(keypad or nfc module cover) | |
| Seals fixed position4 | MD button | |
REGISTER
| Energy | Active energy | Comply |
| Reactive energy | Comply | |
| Apparent energy | / | |
| Demand | Calc method | Slide |
| Period | 15 min | |
| Number Of Interval | 3 | |
| Active energy | Comply | |
| Reactive energy | Comply | |
| Apparent energy | / | |
| Instantaneous value | Voltage | Comply |
| Current | Comply | |
| Active power | Comply | |
| Reactive power | Comply | |
| Apparent power | Comply | |
| Frequency | Comply | |
| Power factor | Comply |
OTHERS HARDWARE
| RTC | Accuracy | < 0.5s/d |
| Subsidiary power | Super capacitor | Comply (for last gasp) |
| Internal battery | Comply | |
| External replaced battery | Comply | |
| Measurement elements | Phase line | CT |
| Neutral line | Shunt, meter need to be able to detect neutral missing as right image |
LOAD PROFILE
| Monthly billing | Billing count | Last 12th |
| Billing time | The default billing time is 00:00:00 of the 1th day in each month. | |
| Billing data |
1. Date and Time 2. Active Energy import total +A (1.8.0) 3. Active Energy export total -A (2.8.0) 4. Reactive Energy import total +R (3.8.0) 5. Reactive Energy export total -R (4.8.0) 6. Active Energy in kWh for the current billing period 7. Reactive Energy in Varh for the current billing period 8. Remaining balance 9. Charging Amount of Current month 10. Current month consumption amount 11. Active maximum power 12. Reactive maximum power |
|
| Daily billing | Billing count | 62 |
| Billing time | The default billing time is 00:00 of each day. | |
| Billing data |
1. Date and Time 2. Active Energy import total +A (1.8.0) 3. Active Energy export total -A (2.8.0) 4. Reactive Energy import total +R (3.8.0) 5. Reactive Energy export total -R (4.8.0) 6. Available credit 7. Current month consumption Amount |
|
Load profile |
Capture period |
15 min |
|
Entries |
100 days |
|
|
Capture objects (Energy) |
1. Date and Time |
|
|
Capture objects (Quality) |
1. Date and Time |

|
Limiter |
Enable |
Comply |
|
monitor object |
active power import/current |
|
|
Threshold value |
22KW, configurable |
|
|
Othres |
details check sheet 'limiter' |
|
|
Over voltage |
Enable |
Comply |
|
Threshold value |
Over voltage threshold: 250V, configurable |
|
|
Over current |
Enable |
/ |
|
Threshold value |
/ |
|
|
No credit |
Enable |
Comply |
|
Factory settings |
Enable |
/ |
|
Power off |
Enable |
/ |
|
Tamper |
Enable |
Comply |
|
tamper item |
1. Meter cover open, configurable |